Command Line Interface Reference Guide
disable-timer
■ loop-protect disable-timer < 0 to 604800 >
Set time in seconds to wait before attempting to reenable a port.
Range: < 0 to 604800 >
loop-detected
■ [no] loop-protect trap loop-detected
generate trap when a loop is detected
port-list
■ [no] loop-protect [ETHERNET] PORT-LIST
Specify the ports that are to be added to/removed from loop protection.
Next Available Option:
receiver-action
are received on the specified port(s).
receiver-action
■ loop-protect [ETHERNET] PORT-LIST receiver-action < send-disable | no-disable >
Select action to take when loop protect packets are received on the specified port(s).
Supported Values:
■ send-disable
■ no-disable
transmit-interval
■ loop-protect transmit-interval < 1 to 10 >
Set time between packet transmissions.
Range: < 1 to 10 >
trap
■ [no] loop-protect trap
Specify loop protection traps that are to be enabled/disabled.
Next Available Option:
loop-detected
© 2009 Hewlett-Packard Development Company, L.P.
< send-disable | no-disable > -- Select action to take when loop protect packets
-- generate trap when a loop is
(p. 371)