3. Appendix: SP Mode Tables
050 Amount:PCU T-Collect Bottle
[0 to 255 / - / 1 %/step]
Displays the value given by the following formula:
(Current revolution ÷ Target revolution) × 100. This shows how much of the unit's expected
-061 to
lifetime has been used up.
-078
The Rotation% counter is based on rotations, not prints. If the number of rotations reaches
the limit, the machine enters the end condition for that unit. If the print count lifetime is
3
reached first, the machine also enters the end condition, even though the R% counter is still
less than 100%.
061 Rotation (%): PCU: Bk
062 Rotation (%): PCU: C
063 Rotation (%): PCU: M
064 Rotation (%): PCU: Y
065 Rotation (%): Development Unit: Bk
066 Rotation (%): Development Unit: C
067 Rotation (%): Development Unit:M
068 Rotation (%): Development Unit: Y
069 Rotation (%): Developer: Bk
070 Rotation (%): Developer: C
071 Rotation (%): Developer: M
072 Rotation (%): Developer: Y
073 Rotation (%): ITB Unit
074 Rotation (%): ITB Cleaning Unit
075 Rotation (%): Fusing Unit
076 Rotation (%): Fusing Pad
077 Rotation (%): Fusing Belt
078 Rotation (%):PTR Unit