JUNOSe 11.0.x Command Reference Guide A to M
bridge1483 mtu
bridge1483 mtu mtuSize
Syntax
no bridge1483 mtu
Command introduced in JUNOSe Release 7.3.0.
Release Information
Sets the maximum allowable size, in bytes, of the maximum transmission unit (MTU)
Description
for bridged Ethernet interfaces. The no version restores the default MTU size for
bridged Ethernet interfaces, 1518 bytes.
Options
Profile Configuration, Subinterface Configuration
Mode
310
bridge1483 mtu
mtuSize Maximum allowable size of the MTU, in the range 64–9180 bytes;
default value is 1518