aaa tunnel calling-number-format
aaa tunnel calling-number-format
Syntax
{ descriptive [ include-agent-circuit-id ] [ include-agent-remote-id ] |
fixed [ stacked ] |
fixed-adapter-embedded [ stacked ] |
fixed-adapter-new-field [ stacked ] |
include-agent-circuit-id [ include-agent-remote-id ] |
include-agent-remote-id }
no aaa tunnel calling-number-format
Command introduced before JUNOSe Release 7.1.0.
Release Information
include-agent-circuit-id and include-agent-remote-id keywords added in JUNOSe
Release 8.1.0.
stacked keyword added in JUNOSe Release 9.3.0.
fixed-adapter-embedded and fixed-adapter-new-field keywords added in JUNOSe
Release 10.0.0.
Configures the format used by the E Series L2TP access concentrator (LAC) to generate
Description
the L2TP Calling Number attribute value pair (AVP) 22 that it passes to the L2TP
network server (LNS). Available formats include different fixed formats and several
formats that include either or both of the agent-circuit-id (suboption 1) and
agent-remote-id (suboption 2) suboptions of the PPPoE intermediate agent tags. The
no version restores the default calling number format, descriptive.
Options
descriptive Formats calling number AVP in descriptive format that includes
only interface information
descriptive include-agent-circuit-id Formats calling number AVP in descriptive
format to include interface information and the agent-circuit-id suboption
descriptive include-agent-circuit-id include-agent-remote-id Formats calling
number AVP in descriptive format to include interface information and both the
agent-circuit-id and agent-remote-id suboptions
descriptive include-agent-remote-id Formats calling number AVP in descriptive
format to include interface information and the agent-remote-id
fixed Formats calling number AVP to use a fixed format of up to 15 characters
consisting of all ASCII fields, similar to the fixed format of RADIUS attribute 31
(Calling-Station-Id):
Format for ATM interfaces:
systemName (up to 4 bytes) slot (2 bytes) port (1 byte) VPI (3 bytes)
VCI (5 bytes)
Format for Ethernet interfaces:
systemName (up to 4 bytes) slot (2 bytes) port (1 byte) VLAN (8 bytes)
Format for serial interfaces:
Chapter 2: A Commands
aaa tunnel calling-number-format
63
Need help?
Do you have a question about the JUNOSE SOFTWARE 11.0.X - COMMAND REFERENCE A TO M 1-11-2010 and is the answer not in the manual?