frame-relay lmi-n391dte
frame-relay lmi-n391dte keepExchanges
Syntax
no frame-relay lmi-n391dte
Command introduced before JUNOSe Release 7.1.0.
Release Information
Sets the full-status polling counter (N391) on a DTE interface. The no version restores
Description
the default value, assuming an LMI has been configured.
Options
Interface Configuration
Mode
630
frame-relay lmi-n391dte
keepExchanges—Number in the range 1– 255; default value is 6; number of keep
exchanges to be done before requesting a full-status message. If you specify a
value of 1, you receive full-status messages only.