Sflow Receiver; Sflow Sampler - NETGEAR ProSafe GSM7224P User Manual

Prosafe managed switch command line interface (cli) 9.0.2
Hide thumbs Also See for ProSafe GSM7224P:
Table of Contents

Advertisement

sflow receiver

Use this command to configure the sFlow collector parameters (owner string, receiver
timeout, max datagram size, IP address, and port).
Format
sflow receiver <rcvr_idx> owner <owner-string> timeout <rcvr_timeout>
max datagram <size> ip/ipv6 <ip> port <port>
Mode
Global Config
Field
Description
Receiver Owner The identity string for the receiver, the entity making use of this sFlowRcvrTable entry.
The range is 127 characters. The default is a null string. The empty string indicates that
the entry is currently unclaimed and the receiver configuration is reset to the default
values. An entity wishing to claim an sFlowRcvrTable entry must ensure that the entry is
unclaimed before trying to claim it. The entry is claimed by setting the owner string to a
non-null value. The entry must be claimed before assigning a receiver to a sampler or
poller.
Receiver
The time, in seconds, remaining before the sampler or poller is released and stops
Timeout
sending samples to receiver. A management entity wanting to maintain control of the
sampler is responsible for setting a new value before the old one expires. The allowed
range is 0-4294967295 seconds. The default is zero (0).
Receiver Max
The maximum number of data bytes that can be sent in a single sample datagram. The
Datagram Size
management entity should set this value to avoid fragmentation of the sFlow datagrams.
The allowed range is 200 to 9116). The default is 1400.
Receiver IP
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow datagrams will be sent. The
default is 0.0.0.0.
Receiver Port
The destination Layer4 UDP port for sFlow datagrams. The range is 1-65535. The
default is 6343.
no sflow receiver
Use this command to set the sFlow collector parameters back to the defaults.
Format
no sflow receiver <indx> {ip <ip-address> | maxdatagram <size> | owner
<string> timeout <interval> | port <14-port>}
Mode
Global Config

sflow sampler

A data source configured to collect flow samples is called a poller. Use this command to
configure a new sFlow sampler instance for this data source if <rcvr_idx> is valid.
Format
sflow sampler {<rcvr-indx> | rate <sampling-rate> | maxheadersize
<size>}
Mode
Interface Config
ProSafe Managed Switch
Utility Commands
580

Hide quick links:

Advertisement

Table of Contents
loading