Poe Timer Schedule Name; Poe Reset Auto - NETGEAR ProSafe GSM7224P User Manual

Prosafe managed switch command line interface (cli) 9.0.2
Hide thumbs Also See for ProSafe GSM7224P:
Table of Contents

Advertisement

used to reset the PoE port. The command can also reset the power-delivering ports. Note that
this command takes effect only once after it is executed and cannot be saved across power
cycles.
Format
poe reset
Mode
Global Config
Interface Config

poe reset auto

Use this command to set the auto-reset mode. When auto-reset mode is enabled, the PoE port
will be automatically reset if an error, such as overload, is detected on the port. By default the
auto reset mode is enabled. This command allows you to set the mode based on each individual
PoE unit or all PoE units.
Format
poe reset auto {<unit>|all}
Mode
Global Config
Default
Enable
no poe reset auto
Use this command to clear autoreset mode.
Format
no poe reset auto {<unit>|all}
Mode
Global Config

poe timer schedule name

Use this command to allow you to attach a timer schedule to a PoE port.
You can define a time schedule using the existing time range commands. This schedule has start
and stop times. When this timer schedule is applied to a PoE-enabled port, the capability of the
port to deliver power is affected. At the scheduled start time, the PoE port is disabled such that it
cannot deliver any power. At the scheduled stop time, the PoE port is reenabled so that it can
deliver power.
Note:
For information about creating a timer schedule, see
Commands for Time-Based ACLs
Format
poe timer schedule <name>
Mode
Interface Config
ProSafe Managed Switch
on page 485.
Power over Ethernet (PoE) Commands
495
Time Range

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents