Clock Summer-Time Date - NETGEAR ProSafe GSM7224P User Manual

Prosafe managed switch command line interface (cli) 9.0.2
Hide thumbs Also See for ProSafe GSM7224P:
Table of Contents

Advertisement

Use the following parameters to configure the summer-time.
USA—the US Daylight saving time setting is used (Start --- March, 2nd sunday 02:00 AM,
End --- Nov, 1st sunday, 2:00 AM)
EU—the European Union Daylight savings time is used (Start --- March, 5th Sunday
02:00 AM, End --- October, 5th Sunday, 3:00 AM)
week—Week of the month. (Range: 1-5, first, last)
day—Day of the week. (Range: The first three letters by name; sun, for example.)
month—Month. (Range: The first three letters by name; jan, for example.)
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh:0-23, mm: 0-59)
offset—Number of minutes to add during the summertime. (Range:1-1440)
acronym—The acronym for the time zone to be displayed when summertime is in effect.
(Range: Up to four characters)
Format
clock summer-time recurring {USA | EU | {week day month hh:mm week
day month hh:mm}} [offset offset ] [zone acronym]
Mode
Global Config
For example:
(Switch)(Config)# clock summer-time recurring 1 sun jan
00:10 2 mon mar 10:00 offset 1 zone ABC

clock summer-time date

Use the clock summer-time date command to set the summertime offset to UTC. If the
optional parameters are not specified, they are read as either '0' or '\0', as appropriate.
date—Day of the month. (Range: 1-31)
month—Month. (Range: The first three letters by name; jan, for example.)
year—Year. (Range: 2000-2097)
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh: 0-23, mm: 0-59)
offset—Number of minutes to add during the summertime. (Range:1-1440)
acronym—The acronym for the time zone to be displayed whensummertime is in effect.
(Range: Up to four characters)
Format
clock summer-time date {date | month} {month | date} year hh:mm
{date| month} {month | date} year hh:mm [offset offset ] [zone
acronym]
Mode
Global Config
For example:
(Switch)(config)# clock summer-time date 1 Apr 2007
02:00 28 Oct 2007 offset 90 zone EST
ProSafe Managed Switch
Utility Commands
540

Hide quick links:

Advertisement

Table of Contents
loading