Use the following parameters to configure the summer-time.
•
USA—the US Daylight saving time setting is used (Start --- March, 2nd sunday 02:00 AM,
End --- Nov, 1st sunday, 2:00 AM)
•
EU—the European Union Daylight savings time is used (Start --- March, 5th Sunday
02:00 AM, End --- October, 5th Sunday, 3:00 AM)
•
week—Week of the month. (Range: 1-5, first, last)
•
day—Day of the week. (Range: The first three letters by name; sun, for example.)
•
month—Month. (Range: The first three letters by name; jan, for example.)
•
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh:0-23, mm: 0-59)
•
offset—Number of minutes to add during the summertime. (Range:1-1440)
•
acronym—The acronym for the time zone to be displayed when summertime is in effect.
(Range: Up to four characters)
Format
clock summer-time recurring {USA | EU | {week day month hh:mm week
day month hh:mm}} [offset offset ] [zone acronym]
Mode
Global Config
For example:
(Switch)(Config)# clock summer-time recurring 1 sun jan
00:10 2 mon mar 10:00 offset 1 zone ABC
clock summer-time date
Use the clock summer-time date command to set the summertime offset to UTC. If the
optional parameters are not specified, they are read as either '0' or '\0', as appropriate.
•
date—Day of the month. (Range: 1-31)
•
month—Month. (Range: The first three letters by name; jan, for example.)
•
year—Year. (Range: 2000-2097)
•
hh:mm—Time in 24-hour format in hours and minutes. (Range: hh: 0-23, mm: 0-59)
•
offset—Number of minutes to add during the summertime. (Range:1-1440)
•
acronym—The acronym for the time zone to be displayed whensummertime is in effect.
(Range: Up to four characters)
Format
clock summer-time date {date | month} {month | date} year hh:mm
{date| month} {month | date} year hh:mm [offset offset ] [zone
acronym]
Mode
Global Config
For example:
(Switch)(config)# clock summer-time date 1 Apr 2007
02:00 28 Oct 2007 offset 90 zone EST