User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software

set gvrp interfacemode all

This command enables GVRP (GARP VLAN Registration Protocol) for all ports.
Default
Format
Mode

no set gvrp interfacemode all

This command disables GVRP (GARP VLAN Registration Protocol) for all ports. If GVRP is
disabled, Join Time, Leave Time and Leave All Time have no effect.
Format
Mode

show gvrp configuration

This command displays Generic Attributes Registration Protocol (GARP) information for one or
all interfaces.
Format
Mode
Interface
Join Timer
Leave Timer
LeaveAll Timer
Switching Commands
disabled
set gvrp interfacemode all
Global Config
no set gvrp interfacemode all
Global Config
show gvrp configuration {<slot/port> | all}
Privileged EXEC and User EXEC
Valid slot and port number separated by forward slashes.
Specifies the interval between the transmission of GARP PDUs registering (or
re-registering) membership for an attribute. Current attributes are a VLAN or
multicast group. There is an instance of this timer on a per-Port, per-GARP par-
ticipant basis. Permissible values are 10 to 100 centiseconds (0.1 to 1.0 sec-
onds). The factory default is 20 centiseconds (0.2 seconds). The finest
granularity of specification is 1 centisecond (0.01 seconds).
Specifies the period of time to wait after receiving an unregister request for an
attribute before deleting the attribute. Current attributes are a VLAN or multi-
cast group. This may be considered a buffer time for another station to assert
registration for the same attribute in order to maintain uninterrupted service.
There is an instance of this timer on a per-Port, per-GARP participant basis. Per-
missible values are 20 to 600 centiseconds (0.2 to 6.0 seconds). The factory
default is 60 centiseconds (0.6 seconds). The finest granularity of specification
is 1 centisecond (0.01 seconds).
This Leave All Time controls how frequently LeaveAll PDUs are generated. A
LeaveAll PDU indicates that all registrations will shortly be deregistered. Par-
ticipants will need to rejoin in order to maintain registration. There is an
202-10088-01, March 2005