In the following cases, set the pointer No. common to sequence programs.
 When creating the sequence programs with the multi-program method
 When creating sequence programs of main process with ST language
This operation is required every time a new project is created, and parameter files must be written to the CNC controller.
Note
 If no value is set to the common pointer No., "P1800" will be set.
When a simple project (with labels) or a structured project is newly created, or when "Project Type" is changed to any of the
said project, "2048" is automatically set to "Common Pointer No." as the default value if its setting has been blank.
(1) Select [PLC System] tab.
(2) Set a numeric value in [Common Pointer No.], and click [End] on the following screen.