Mitsubishi Electric M800VW Series Manual page 117

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items
 If the set values for devices are illegal
If there is a problem with the device setting value, the following error dialog will appear when writing the sequence programs
to the CNC controller. Set the number of device points as explained above in this case.
 Setting example of the number of devices (Project 1)
The setting example of the number of devices for the project 1 is described below.
Populate the device setting parameter of GX Works2 with the sum of device points and device common points of project 1 set
in built-in PLC (built-in edit function) as this example shows.
GX Works2
Dialog box for parameter setting (Device setting)
IB-1501614-B
Device setting window of built-in PLC
built-in edit function
[Example: M device]
Set 27360 (= device points [17120] + device common
points [10240]) in GX Works2 device setting parameters
for project 1
Setting for the number of device common points
Set device points for project 1
92