Fixed Device Assignment - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
2 System Configuration of H/W
2.2 Relation of RIO Unit and Devices

2.2.2.1 Fixed Device Assignment

 By setting the parameter "#53001 RIO dev assign" to "0", the PLC device assignment method, which is to be used for input/
output of each remote I/O unit station, will be the fixed device assignment.
 PLC devices assigned for each remote I/O unit station at the time of the fixed device assignment are as follows:
Channel No.
Input device
RIO1
Output device
Input device
RIO2
Output device
Input device
RIO3
Output device
Note
(1) Do not use the input/output signals of the system-occupied stations of RIO3 and operation panel I/O unit-connected
channels.
 A part of PLC devices assigned for each station of remote I/O units can input/output signals with PLC high speed by setting
the high-speed input/output specification parameters or R registers.
- The devices for inputting/outputting signals with PLC high speed can be set individually for the high-order and the low-
order per 16 points for DI and DO of each remote I/O unit station.
- Only devices of the first to eighth stations for each remote I/O channel can input/output signals with PLC high speed.
The devices of the ninth to 64th stations input/output with PLC medium speed.
- The parameter and R register numbers for the high-speed input/output designation are as follows:
Channel No.
High-speed input specification
RIO1
High-speed output specification
High-speed input specification
RIO2
High-speed output specification
High-speed input specification
RIO3
High-speed output specification
Note
(1) The above parameters are invalid when the devices have been assigned arbitrarily.
(2) Refer to "PLC Programming Manual" for details of the setting method.
1
2
...
X0000
X0020
...
to X001F
to X003F
Y0000
Y0020
...
to Y001F
to Y003F
X0100
X0120
...
to X011F
to X013F
Y0100
Y0120
...
to Y011F
to Y013F
X0200
X0220
...
to X021F
to X023F
Y0200
Y0220
...
to Y021F
to Y023F
1 to 4
Parameter No.
R register No.
R7828 low-order
# 6457
R7830 low-order
# 6461
R7829 low-order
# 6459
R7831 low-order
# 6463
R7832 low-order
# 6465
R7836 low-order
# 6473
9
Station No.
8
9
...
X00E0
ZR5000
...
to X00FF
/ZR5001
Y00E0
ZR6000
...
to Y00FF
/ZR6001
X01E0
ZR5200
...
to X01FF
/ZR5201
Y01E0
ZR6200
...
to Y01FF
/ZR6201
X02E0
ZR5400
...
to X02FF
/ZR5401
Y02E0
ZR6400
...
to Y02FF
/ZR6401
Station No.
Parameter No.
# 6458
# 6462
# 6460
# 6464
# 6466
# 6474
63
64
ZR5108
ZR5110
/ZR5109
/ZR5111
ZR6108
ZR6110
/ZR6109
/ZR6111
ZR5308
ZR5310
/ZR5309
/ZR5311
ZR6308
ZR6310
/ZR6309
/ZR6311
ZR5508
ZR5510
/ZR5509
/ZR5511
ZR6508
ZR6510
/ZR6509
/ZR6511
5 to 8
R register No.
R7828 high-order
R7830 high-order
R7829 high-order
R7831 high-order
R7832 high-order
R7836 high-order
IB-1501614-B