2 System Configuration of H/W

2.8 Outline of Analog Signal Output Circuit

2.8 Outline of Analog Signal Output Circuit
 Output circuit
AIO
Load
500Ω
AO
0V
 Output conditions
Analog output voltage
-10 V to 10 V (±5%)
Resolution
10 V / 4095 = 2.44 mV
Load conditions
10 kΩ load resistance
Output resistance value
500 Ω
IB-1501614-B
DAC
26