M800V/M80V Series PLC Development Manual
9 Appendix 3: PLC Function
9.1 Enhanced PLC Security Mode
Operation procedure
To use the E/U mode, configure the setting by following the steps below.
(1) Determine the setting details
(2) Set the multi-project parameters
(3) Create MTB programs
(4) Set NC parameters (E/U customization setting)
(5) Save an empty E/U project
(6) Provide information to end users
(1) Determine the setting details
When the E/U mode setting is desired, MTB must decide the setting details of the following items.
Setting item
E/U project No.
Number of devices
E/U open device
Project execution order
Maximum number of steps
MTB program
Enhanced PLC security mode
IB-1501614-B
The project number to be used as the E/U project among multi-projects
The number of available devices for the projects including the E/U project
A range of project-common devices (Y, M, D) that are used by the E/U project
The execution order of the projects including the E/U project
The maximum value for the total number of steps of a sequence program that can be stored in
each of the projects including the E/U project
A sequence program executed by an MTB project
Machine control programs and E/U open interface are included
Security setting for MTB projects (write protect or read/write protect)
610