M800V/M80V Series PLC Development Manual
9 Appendix 3: PLC Function
9.1 Enhanced PLC Security Mode
9.1.4 Information to be Shared with End Users
When the E/U mode is enabled, provide the information about the built-in PLC and the E/U mode to end users.
The information to be provided to end users are as follows:
CNC Manual
E/U project No.
Limitations on instructions
Limitations on devices
Limitations on functions
Maximum number of steps for E/U project
Common devices for E/U open interface and the meaning of the signals to be assigned
Example of E/U program
Precautions
CNC Manual
End users need to know the specifications of the built-in PLC in M800V/M80V series NCs to create sequence programs.
Provide "PLC Development Manual" (this manual) and "PLC Programming Manual".
E/U project No.
Inform end users which project is the E/U project among the multi-projects.
Limitations on instructions
The following dedicated instructions cannot be used in E/U programs
S.ROT, S.ATC, G(P).RIRD, G(P).RIWT, Z(P).REMFR, Z(P).REMTO
Inform end users that these instructions are unavailable.
IB-1501614-B
618