Mitsubishi Electric M800VW Series Manual page 134

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.5 Common Items
Item
Trace Count Setting
Total Count
Count Before Trigger
Additional Information
Time
Program Name
Data Acquisition Timing Setting
Trigger Condition Setting
(*1) If time information is added, the size of traceable data becomes smaller than usual by [4 bytes] × [Trace Count].
(*2) When selecting Detail Setting, click [Setting Change...] and configure settings as follows.
Item
Device/Label
Device
Comment
Condition
Bit device
Word device
Radix (Word device only)
Values (Word device and "=" only)
(*1) Refer to "5.5.11.2 Basic Specifications" for the devices that can be set.
1 to 8192
0 to Total Count -1
Optional (*1)
Not check
Each scan or Detail Setting (*2)
At the Time of Manual Trigger Execution or Detail Setting (*2)
Device or label to be used in condition (*1)
Display the device corresponds to "Device/Label".
Display the device comment of "Device /Label".
at the rising ( ↑ ), or at the falling ( ↓ )
=, or Change
Decimal or hexadecimal
Optional
109