M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.13 NC File Operation Menus

6.13.8 Format Popup Screen

6.13.8.1 Outline

This is used to format the temporary storage area in the NC.

6.13.8.2 Screen Display Items

The following table describes the screen display items for the format popup screen.
Item name
Create default data after formatting

6.13.8.3 Default Data

If the [Create default data after formatting] check box in the format popup screen is selected, the following PLC data is created
after formatting the temporary storage area in the NC.
Data classification
Data name
Program
MAIN
Parameter
PARAM
A project created with default data is handled as a project without labels.

6.13.8.4 Enabled/Disabled State of Menu Keys

The following table describes the conditions upon which menu keys displayed on the FORMAT popup screen are enabled/
disabled. Menu keys not displayed in the following table is always enabled.
Menu name
Default Data
This is displayed with the check box not selected.
Hidden when operation mode of the project is GX Works2.
Blank program with only an END instruction
Parameters inherited from device settings for the formatted project.
Condition upon which it is enabled/disabled
Enabled when operation mode of the project is GX Developer.
Hidden when operation mode of the project is GX Works2.
Display state
Description