M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.11 Basic Operation

6.11.4.3 Editing and Debugging the Sequence Program

The following diagrams illustrate the procedure to edit and debug sequence programs stored in the NC.
To use only one project
Procedure
After the PLC on-board starts, the system automatically reads
PLC data and transitions to the ladder screen. The monitor
Start
also starts.
Main/ladder
Stop the PLC.
PLC RUN/STOP
Main/ladder
Edit the ladder.
Main/ladder
Main/ladder
Monitor the ladder.
Main/ladder
Run the PLC.
PLC RUN/STOP
Main/ladder
Test the device.
Main/ladder
Switch programs.
Complete
IB-1501614-B
Operation
Screen position
PLC RUN/STOP
STOP EXECUTE
EDIT
Edit the ladder.
CONVERT LADDER
MONITOR
PLC RUN/STOP
RUN EXECUTE
DEVICE TEST
Test the device.
PROGRAM CHANGE
Switch to a program that has not yet been edited.
328
Menu button
Display the PLC RUN/STOP popup
screen.
Stop the PLC.
Switch to the edit mode.
Edited ladder data is confirmed by the
conversion operation.
Switch to the monitor mode.
Display the PLC RUN/STOP popup
screen.
Run the PLC.
Display the device test popup screen.
Repeat the edit and debug procedure
until the debug results are correct.
Display the switch program screen.
Continue switching programs until all
sequence programs have been edited
and debugged.