M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.1 Outline

6.1.3 Operation Mode of Project

Operation mode settings
Use the bit selection parameters to set whether the project operated on the PLC on-board operates as a GX Developer
project or a GX Works2 project.
Operation mode is allocated with bit selection parameter as follows: This parameter is enabled when the PLC on-board is
restarted.
(1) For the machine sequence
Parameter
Bit
R7835-H(#6472)
bit0
bit1
bit2
bit3
bit4
bit5
bit6
bit7
(2) User safety sequence
Parameter
Bit
R7835-L(#6471)
bit6
bit7
Operation mode and readable project
The combination of the operation mode and readable project is as follows.
Operation mode
GX Works2
GX Works2
Simple project
Without labels
GX Works2
Simple project
With labels
GX Works2
Structured project
GX Developer
Without labels
GX Developer
With labels
GX Developer
GX Works2
Simple project
Without labels
GX Works2
Simple project
With labels
GX Works2
Structured project
GX Developer
Without labels
GX Developer
With labels
(*1) Readable when there is no symbolic information.
IB-1501614-B
Item
Operation Mode of Project No.1
Operation Mode of Project No.2
Operation Mode of Project No.3
Operation Mode of Project No.4
Operation Mode of Project No.5
Operation Mode of Project No.6
Reserve
Reserve
Item
Safety PLC "SafePLC1" operation
mode
Safety PLC "SafePLC2" operation
mode
Project type
Reading of project
× (*1)
× (*1)
× (*1)
0: Operates as a GX Developer project
1: Operates as a GX Works2 project
0: Operates as a GX Developer project
1: Operates as a GX Works2 project
Operates as a project without labels when there
is no symbolic information
Operates as a project without labels when there
is no symbolic information
Operates as GX Works2 project
Operates as a GX Works2 project without labels
when there is no symbolic information
Operates as a GX Developer project
Operates as a GX Developer project without la-
bels when there is no symbolic information
Operates as a GX Developer project without la-
bels when there is no symbolic information
Operates as a project without labels
260
Setting value
Setting value
Remarks