Mitsubishi Electric M800VW Series Manual page 224

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.10 Creating Label
 Local label for program
Data format of col-
umns
Class
 Describe the class name of label.
Conversion cannot be done without class name. Always describe a device.
 Types of class are described later.
Label name
 Describe label name.
Conversion cannot be done without label name. Always describe a device.
 Up to 32 one-byte characters can be described.
 Actual device names and reserved characters cannot be used.
Data type
 Describe the data type of label.
Conversion cannot be done without data type. Always describe a device.
 Data types are described later.
Constant
 Describe numeric value assigned to label when the class is VAR_CONSTANT.
Device
 Cannot be set for local label.
Comment
 Describe comment of label.
 Up to 1024 one-byte characters can be described.
Save the above data in the Unicode format, and change the extension to ".csv".
The first two rows are for
Header. Input "Label" and
the column data format in
the table below in an
appropriate language.
Input class, label and other
information in the same
row.
Description