M800V/M80V Series PLC Development Manual
5 Peripheral Development Environment (GX Works2)
5.7 Developing Structured Project
How to check conversion step with an error number
Error steps can be checked using PLC verify function.
For details on PLC verify function, refer to "5.7.7 Verifying the Sequence Programs".
Verify Source: Select transfer source ladder file on GX Works2
Verify Destination: Select ladder with an error file "ERRLD-00" in the CNC controller
When PLC verification is executed, the verify result screen is displayed. When a file name is double-clicked, mismatched
contents are displayed as shown in the example below. The NOP instructions on the CNC controller are the steps with
conversion errors.
Double-click one of them to display and edit the corresponding part on the GX Works2 file.
"<Verify Source>" indicates the GX Works2 side, and "<Verify Destination>" the CNC controller side.
Result with error is displayed in red
CNC controller
GW Works2
IB-1501614-B
162