M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.13 NC File Operation Menus
Abnormal operation
This information describes the details of error messages displayed on the PLC version up screen and the corrective action
thereof.
Error message
A Version up Data is not selected.
The version up cannot be executed be-
cause the PLC is running. Execute again af-
ter stopping the PLC.
The temporary data cannot be created in
the specified drive. The following are possi-
ble causes.
 The drive capacity is not enough.
 The drive is write protected.
 The directory for the temporary data
"WorkTemp" already exists.
A faulty command exist in the program. Ex-
ecute a program check and correct the pro-
gram.
Device point that is set in parameter is not
match the device point in NC. Continue the
reading PLC or writing PLC?

6.13.12.7 Closing the PLC Version Up Screen

Use any of the following methods to close the PLC version up screen.
Methods to close the screen
Press the [CLOSE] menu key.
Press the left arrow key.
Press the [ESC] key on the software keyboard.
Error details
This is displayed when you press the [EXE-
CUTE] menu key without selecting any PLC
data from the list.
This is displayed when you attempt to update
the PLC data stored in the NC without stopping
the PLC.
When you use "Method for Directly Storing the
PLC Data File in "ladXX" Directory" described
in "6.13.13.5 Storing Method of the Updating
Version Data" to store the updating version da-
ta, the temporary data directory "WorkTemp" is
created in the storage destination. This mes-
sage is displayed in the following cases.
(1) The free capacity is insufficient.
(2) The external device is write protected.
(3) A directory or file named "WorkTemp" ex-
ists.
This is displayed when you attempt to update
the program containing any device No. which is
out of the device range of the NC.
This is displayed when the parameter file to be
updated has different number of device points
from that of the NC.
When selecting [YES], reading of the parame-
ter file is skipped and the update process is
continued.
When selecting [NO], the update process is
cancelled.
389
Remedy
Select PLC data from the list before pressing
the [EXECUTE] menu key.
Update the PLC data stored in the NC after
stopping the PLC.
Perform the following for the external device
that contains the updating version data, before
updating the PLC data version.
Increase the free capacity (For required free
capacity, refer to "Method for Directly Storing
the PLC Data File in "ladXX" Directory" in
"6.13.13.5 Storing Method of the Updating Ver-
sion Data".)
(1) Release the write protection
(2) Delete or rename the "WorkTemp" directory
or file
Check the device range and correct the pro-
gram to be updated, so that all the devices in
the program are within the range.
When updating the version of parameter file,
check the number of NC device points shown in
"6.18.6 Device Settings Screen", and match
the number.