Enabled/Disabled State Of Menu Keys; Status During Screen Displays; Operation Of Key Presses; Setting The Program Execution Sequence - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
6 Explanation of Built-in Editing Function (PLC On-board)
6.18 Parameter Menus

6.18.2.3 Enabled/Disabled State of Menu Keys

The following table describes the conditions upon which menu keys displayed on the program settings screen are enabled/
disabled.
The menu keys which are not described in the following table are always enabled.
Menu name
Inserting lines
Deleting lines
Complete settings
Select data

6.18.2.4 Status during Screen Displays

The following table describes the status when displaying the program settings screen.
Item name
Execution sequence
This displays the details of the program settings for the current project.
This displays the selectable execution type and files names of sequence programs stored
Contents of setting
in the current project.

6.18.2.5 Operation of Key Presses

The following table describes the operation of each menu key and the keys on the NC keyboard when pressed.
Item name
Left arrow key
Execution sequence
Inserting lines
Deleting lines
Complete settings
Close

6.18.2.6 Setting the Program Execution Sequence

(1) Press the [EXE. ORDER] menu key to select the execution order.
(2) Use the up/down arrow keys, "PageUp" key, and "PageDown" key to move the cursor to the position in the program name
column to set the execution sequence for programs.
(3) Press the [INPUT] key. Pressing the [INPUT] key selects the select program field of Contents of setting.
(4) Use the up/down arrow keys, "PageUp" key, and "PageDown" key to select the program for which you want to set the
program execution sequence.
(5) Press the [INPUT] key. Pressing the [INPUT] key displays the name of the program selected in the select program field at
the cursor position in the execution order.
[WAIT] is automatically set for the execution type in the line where the program is displayed.
(6) Use the right arrow key to move the cursor from the program name column to the execution type column.
(7) Press the [INPUT] key. Pressing the [INPUT] key selects the selection execution field of Contents of setting.
(8) Use the up/down arrow keys, Page Up key, and Page Down key to select the execution type for the program.
(9) Press the [INPUT] key. Pressing the [INPUT] key displays the execution type selected in the select execution field at the
cursor position in the execution order.
(10) Repeat step (3) to step (9) to set the execution sequence for all programs.
(11) Press the [COMPLETE SETTINGS] menu key after all settings are complete.
Condition upon which it is enabled/disabled
Enabled when the focus is set on the execution sequence.
Hidden when operation mode is GX Works2.
Enabled when the focus is set on the execution sequence.
Hidden when operation mode is GX Works2.
Hidden when operation mode is GX Works2.
Hidden when operation mode is GX Works2.
Refer to "6.18.2.8 Closing the Program Settings Screen".
This sets the focus to the execution sequence.
This inserts one blank line at the cursor position in the execution sequence. Lines
are not inserted when data is already set at the last line in the set list.
This deletes one line at the cursor position in the execution sequence and moves
remaining data up one line.
Refer to "6.18.2.6 Setting the Program Execution Sequence".
Refer to "6.18.2.8 Closing the Program Settings Screen".