Follow the sequence of operations as described in the following table to create multiple programs.
Procedure
Add a sequence program
(1)
Configure the execution order of sequence programs
(2)
Edit and debug the sequence program
(3)
Save the sequence program to the internal ROM
(4)
Only a project without labels can be created.
A new program can be added and edited only when operation mode is GX Developer. For setting method of operation mode,
refer to " Operation mode settings".
When operation mode is GX Works2, add or edit a sequence program to a project with GX Works2, and then store the
program in the CNC from an external device. Refer to "6.11.5 Basic Operation 5 (Loading Programs Created with GX
Developer/GX Works2)" for operation method of external device.

6.11.4.1 Adding Sequence Programs

The following diagrams illustrate the procedure to add sequence programs.
To use only one project
Procedure
After the PLC on-board starts, the system automatically reads
PLC data and transitions to the ladder screen. The monitor
Start
also starts.
Main/ladder
Stop the PLC.
PLC RUN/STOP
Main/ladder
Return to the main screen.
Main/ladder
Add sequence program to
the NC.
Main/NC file operation
Main/File operation
Add new data
Main/External file operation
Return to the main screen.
Main/NC file operation
Complete
IB-1501614-B
Operation
Operation
Screen position
Menu button
PLC RUN/STOP
STOP EXECUTE
NC FILE
FILE OPERATION
DATA NEW
DATA NAME
TITLE
ADDITION
324
Display the PLC RUN/STOP popup
screen.
Stop the PLC.
Return to the main screen.
Transition to the NC file operation
screen.
Transition to the file operation screen.
The add new data popup screen
displays.
Create a sequence program similar to
the sample data.
<Sample data>
Data name
Title
MAIN
Machine A
INIT
Initialize
TAIKI
Abnormal process
Return to the NC file operation screen.
Return to the main screen.