(*2) Applicable devices with trace/trigger point details setting
Applicable devices when the project is selected
Bit device: X, Y, M, L, F, SB, B, SM, T (contact), ST (contact), C (contact)
Word device: T (current value), ST (current value), C (current value), D, R, SW, SD, W, ZR
Applicable devices when the user safety sequence is selected
Bit device: X, Y, M, SM, T (contact), T (coil), ST (contact), ST (coil), C (contact), C (coil)
Word device: T (current value), ST (current value), C (current value), D, R (SafePLC1 only), SD, W, ZR
The qualifications, "bit device digit designation" and "word device bit designation", are available for the following device.
The program cannot be searched by label name.
When an inapplicable device is set, an error will be displayed when reading a trace setup file for trace execution.
(*3) Applicable devices with device setting
Applicable devices when the project is selected
Bit device: X, Y, M, L, F, SB, B, SM, T (contact), T (coil), ST (contact), ST (coil), C (contact), C (coil)
Word device: T (current value), ST (current value), C (current value), D, R, SW, SD, W, ZR
Applicable devices when the user safety sequence is selected
Bit device: X, Y, M, SM, T (contact), ST (contact), C (contact)
Word device: T (current value), ST (current value), C (current value), D, R (SafePLC1 only), SD, W, ZR
The qualifications, "bit device digit designation" and "word device bit designation", are available for the following device.
The program cannot be searched by label name.
The following indicates the process of when an inapplicable device has been set.
 If one or more applicable devices already exist, the setting of the inapplicable device will be ignored.
 If no applicable devices exist, an error will be displayed when reading a trace setup file for trace execution.
(*4) For the trace file compatibility
On-board
Read
Read
×
Read
Write
(*) The trace files which can be deleted are limited to the files written by the On-board.
[For the trace file written in NC with GX Developer.]
The trace files written in NC by GX Developer can be read because of the upper compatibility with the Onboard trace files.
[For the multi-project]
The sampling trace can be set up a trace for each project.
The target is the connected project of the connected NC (displayed upper left on the screen). To switch the target, change the
connected project or connected NC. The trace continues with NC even if the target is switched during the trace execution.
For example, even when switching to project 3 and executing the trace after executing the trace by connecting project 1, the
change does not effect to the project 1. Moreover, it is possible to check the trace result of project 1 by reconnecting project 1.
Trace files of GX-Developer
Write
with the trace conditions
supported by Mitsubishi
Electric CNC
Trace files of GX-Developer
with the trace conditions not
supported by Mitsubishi
Electric CNC
Trace files written by the 
Read
On-board
519
GX-Developer
Write
×
IB-1501614-B

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800vs seriesM80vw seriesM80v seriesM850vwM830vwM850vs ... Show all

Table of Contents