Plc Write Protect Mode; Plc Read/Write Protect Mode - Mitsubishi Electric M800VW Series Manual

Plc development
Hide thumbs Also See for M800VW Series:
Table of Contents

Advertisement

M800V/M80V Series PLC Development Manual
9 Appendix 3: PLC Function
9.1 Enhanced PLC Security Mode

9.1.1.3 PLC Write Protect Mode

The PLC write protect mode inhibits PLC on-board and applications, such as GX Developer or GX Works2, from writing
sequence programs and modifying PLC device values for all projects in the built-in PLC. Reading sequence programs and
monitoring PLC device values are allowed.
This prevents accidentally overwriting the sequence programs in the built-in PLC and modifying device values when
sequence programs are read out or device values are monitored by applications.
For details on the application functions available during the PLC write protect mode, refer to "9.1.1.6 Functions Available in
Each Mode".
Built-in PLC
Write protect mode
Project 1
Writing sequence programs and
modifying device values are inhibited
for all projects in built-in PLC
PLC on-board

9.1.1.4 PLC Read/Write Protect Mode

The PLC read/write protect mode inhibits PLC on-board or applications, such as GX Developer or GX Works2, from writing
sequence programs and modifying PLC device values for all projects in the built-in PLC. In addition, it also prohibits them from
monitoring device values.
This prevents an unauthorized user to connect to the built-in PLC from reading/writing the sequence programs in the built-in
PLC and monitoring/modifying PLC device values.
For details on the application functions available during the PLC read/write protect mode, refer to "9.1.1.6 Functions Available
in Each Mode".
Built-in PLC
Read/write protect mode
Project 1
Writing sequence programs and
modifying device values are inhibited
for all projects in built-in PLC
PLC on-board
IB-1501614-B
Project 2
Reading sequence programs and
monitoring device values from built-in
PLC are allowed
GX Developer/
GX Works2
Project 2
Reading sequence programs and
monitoring device values are also
inhibited for all projects in built-in PLC
GX Developer/
GX Works2
604
Project 3
Project 3