huawei(config)#interface sip 0
Are you sure to add SIP interface?(y/n)[n]:y
6.
Configure the basic attributes of the SIP interface.
– Signaling IP address: 17.10.10.10
– Coding mode: text
– Signaling port ID: 5060
– Transfer mode: UDP
– IP address of the primary IMS: 200.200.200.200
– Signaling port ID of the primary IMS: 5060
– Media IP address 1: 17.10.10.10
– Homing domain name of SIP interface: huawei
– SIP profile ID: 1
When the ONU is MA5616 with version of V800R306, run the command as follows:
huawei(config-if-sip-0)#if-sip attribute basic media-ip 17.10.10.10
signal-ip 17.10.10.10 signal-port 5060 transfer udp primary-proxy-ip1
200.200.200.200 primary-proxy-port 5060 home-domain huawei profile-index 1
When the ONU is MA5603T, or MA5616 with a version newer than V800R306, run
the command as follows:
huawei(config-if-sip-0)#if-sip attribute basic media-ip 17.10.10.10
signal-ip 17.10.10.10 signal-port 5060 transfer udp primary-proxy-ip1
200.200.200.200 primary-proxy-port 5060 home-domain huawei sipprofile-
index 1
7.
Configure the optional attributes of the SIP interface.
You can configure the optional attributes such as the domain name, description,
register server uniform resource identifier (URI), phone context and conference
factory URI by running the if-sip attribute optional command. No configuration
here.
8.
Reset the SIP interface.
huawei(config-if-sip-0)#reset
Are you sure to reset SIP interface?(y/n)[n]:y
huawei(config-if-sip-0)#quit
9.
Configure the PSTN user data.
Configure the telephone number of the user on port 0/2/0 to 0/2/23, telephone number
of the user from 83110001 to 83110024, and terminal ID to 0.
NOTE
l The ONU configured with an ASRB board has 32 POTS ports and an MA5616 configured with
an ASPB board has 64 POTS ports. Configuring 24 PSTN users is used as an example.
l To configure the PSTN data of a single user, run the sippstnuser add command.
l To configure the PSTN data of multiple users in batches, run the sippstnuser batadd command.
huawei(config)#esl user
huawei(config-esl-user)#sippstnuser batadd 0/2/0 0/2/23 0 telno 83110001
10. Change the call priority of the PSTN user.
Configure the call priority of the user on port 0/2/0 to Cat2 and the users of 0/2/1 to
0/2/23 to Cat3 (Default)
huawei(config-esl-user)#sippstnuser attribute set 0/2/0 priority cat2
huawei(config-esl-user)#quit
11. Modify the attributes of all the PSTN ports so that the PSTN ports support the polarity