SmartAX MA5616 Multi-service Access Module
Configuration Guide
------------------------------------------------------------------------------
DigitalID Name
----------------------------------------------------------------------------
huawei(config-if-power4830-2)#power battery parameter 1 0.15 60 75
huawei(config-if-power4830-2)#power module-num 2
huawei(config-if-power4830-2)#power temperature-off battery-off-state permit
huawei(config-if-power4830-2)#power environment humidity 80 10 100 0
This command is invalid unless in the condition of install the sensor, would
you continue? (y/n)[n]:y
huawei(config-if-power4830-2)#power environment temperature 68 -5 80 -20
This command is invalid unless in the condition of install the sensor, would
you continue? (y/n)[n]:y
huawei(config-if-power4830-2)#power outside_digital 1 available-level low-level
digital_alarm 11 name Fan
huawei(config-if-power4830-2)#power outside_digital 3 available-level low-level
digital_alarm 19 name SPD
huawei(config-if-power4830-2)#display power system parameter
EMU ID: 2
----------------------------------------------------------------------------
Charge control state: Automatic control
Equalizing voltage
Charge Lmt quotiety : 0.15
Battery number
battery temperature test upper :
temperature redeem quotiety
battery temperature alarm upper:
Battery off permit
AC over alarm volt
DC over alarm volt
Power module number : 2
module 0 address: 1
module 1 address: 2
Battery high-temperature-off permit
Battery high-temperature-off temperature: 53 C
----------------------------------------------------------------------------
huawei(config-if-power4830-2)#display power environment parameter
EMU ID: 2
----------------------------------------------------------------------------
AnalogID Name
----------------------------------------------------------------------------
DigitalID Name
----------------------------------------------------------------------------
huawei(config-if-power4830-2)#display power alarm
EMU ID: 2
----------------------------------------------------------------------------
Mains supply yes : yes
Total vol lack
Load fuse 0
Load off
Battery 1 loop
Environment Temperature : Normal
Door alarm
The "Door alarm" alarm is generated because the door of the cabinet is not closed.
Fog alarm
Wiring alarm
Battery 1 Temp-Sensor
Environment Humidity-Sensor : Invalid
Issue 04 (2011-10-30)
Available Level|DigitalID Name
0
-
2
-
4
-
6
-
: 56.50V
: 1
: Permit
: 280V
: 58 V
module 0 switch state
module 1 switch state
0
Temperature
1
Humidity
available Level
0
-
2
-
4
-
6
-
: Normal
: Connect
: on
: connect
: Alarm
: Normal
: Normal
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
|
1
1
|
3
1
|
5
1
Power system information
Floating voltage
Equalizing time
Battery 0 capacity
80C
battery temperature test lower: -20C
: 80mV
50C
battery temperature alarm lower: 0C
Battery off voltage
AC lack alarm voltage : 180V
DC lack alarm voltage : 45 V
: Permit
Power environment configuration parameter
AlmUpper AlmLower TestUpper TestLower Unit
68
-5
80
80
10
100
|DigitalID Name
1
|
1
1
|
3
1
|
5
1
Power alarm information
Mains supply lack : normal
battery off
Environment Humidity
Water alarm
Battery Temperature alarm
Acinput air switch
: Invalid
Environment 1 Temp-Sensor
3 Basic Configuration
Available Level
-
-
-
: 53.50V
: 60 days
: 75
AH
: 43.00V
: On
: On
-20
C
0
%R.H.
available Level
Fan
SPD
-
: on
: Normal
: Normal
: Normal
: Normal
1
1
1
Type
Current
Current
0
0
1
//
: Invalid
144