Configuration Guide
The MA5616 requires that the terminal prefixes of PSTN users, ISDN BRA users, and ISDN
PRA users on the same H.248 interface are either the same or different. Note this when
configuring the terminal prefix.
huawei(config-if-h248-0)#tid-format pstn prefix huawei template 6
Step 6 Start the MG interface.
Reset the MG interface to make the MG interface register with the MGC (and to make the
modified attributes of the MG interface take effect) so that the MG interface can work in the
normal state. The MG interface can be started in different manners (see Parameter Description
of the reset command). For a newly configured MG interface, start the MG interface in a cold
start manner.
huawei(config-if-h248-0)#reset coldstart
Are you sure to reset MG interface?(y/n)[n]:y
Step 7 Query the running status of the MG interface.
After the MG interface is interconnected with the MGC successfully, the MG interface needs to
be in the normal state, indicating that the MG interface works in the normal state.
huawei(config-if-h248-0)#quit
huawei(config)#display if-h248 all
------------------------------------------------------------------------------
MGID
------------------------------------------------------------------------------
0
------------------------------------------------------------------------------
Step 8 Configure the PSTN user data.
Add POTS users phone 0-phone 31 so that the users can go online.
huawei(config)#esl user
huawei(config-esl-user)#mgpstnuser batadd 0/3/0 0/3/31 0
Step 9 Configure the local digitmap.
After the configuration, the MA5616 matches the phone number according to the local digitmap
if the MGC does not send the detailed digitmap to the MA5616.
huawei(config-esl-user)#quit
huawei(config)#local-digitmap add huawei normal ([2-8]xxxxxxx|[2-8]xxSxxxxxxx|
13xxxxxxxxx|0xxxxxxxxx)
Step 10 Configure the polarity reversal charging function.
Configure the physical attributes of the PSTN port to which the user belongs to support the
polarity reversal pulse, so that the user can support the polarity reversal charging.
huawei(config)#pstnport
huawei(config-pstnport)#pstnport attribute batset 0/3/0 0/3/31 reverse-pole-pulse
enable
Step 11 Save the data.
huawei(config-pstnport)#quit
huawei(config)#save
----End
Issue 04 (2011-10-30)
CAUTION
Trans State
UDP
Normal
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8 Configuration Example of Services on the MA5616
Through GPON Upstream Transmission
MGPort MGIP
2944 10.10.10.10
MGCPort MGCIP/DomainName
2944
10.10.20.20