Huawei SmartAX MA5616 Configuration Manual page 32

Multi-service access module
Table of Contents

Advertisement

SmartAX MA5616 Multi-service Access Module
Configuration Guide
Figure 3-11 Flowchart for outband management in the telnet mode
Procedure
Step 1 Set up the configuration environment.
Figure 3-9
actual requirements and conditions.
Step 2 In the meth mode, run the ip address command to configure the IP address and subnet mask of
the maintenance Ethernet port of the MA5616.
huawei(config)#interface meth 0
huawei(config-if-meth0)#ip address 10.10.20.2 24
Step 3 Add a route.
l If the configuration environment is set up as shown in
Issue 04 (2011-10-30)
Start
Set up the configuration
environment
Configure the IP address
and subnet mask of the
maintenance port
Is it a WAN environment?
Yes
Add a route
Start Telnet on the
maintenance terminal
Log in to the system
End
or
Figure 3-10
NOTE
The default IP address of the maintenance Ethernet port is 10.11.104.2, and the subnet mask is
255.255.255.0. You can configure the IP address of the maintenance Ethernet port based on the actual
network planning.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
No
shows how to set up the configuration environment according to the
3 Basic Configuration
Figure
3-9, you need not add a route.
21