SmartAX MA5616 Multi-service Access Module
Configuration Guide
Run the quit command to quit the miniesc mode, and then run the save command to save the
data.
----End
Result
After the configuration, the ESCM works in the normal state and monitors the analog and digital
parameters set on the MA5616.
l
l
Example
Table 3-25
Table 3-25 Data plan for configuring the ESCM
Item
EMU
Analog
parameters
Issue 04 (2011-10-30)
When an analog parameter measured is not within the upper and lower alarm thresholds
preset in the system, the MA5616 reports an alarm.
When the actual level of a monitored digital parameter is different from the valid level
preset in the system, the MA5616 reports an alarm.
shows the data plan for configuring the ESCM.
Data
Type: ESCM (MiniESC)
SN: 3
Subnode ID: 8
NOTE
The hardware DIP switch on
the ESCM ranges from 0–15
and therefore the subnode
ID ranges from 0–15.
Ensure that the hardware
DIP switch on the ESCM is
set the same as that of the
EMU subnode on the
device.
This topic uses value 8 as an
example.
Analog parameter ID: 0
Upper alarm threshold of
analog parameter 0: 54°C
Lower alarm threshold of
analog parameter 0: 6°C
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Remarks
The ESCM is displayed as MiniESC on the CLI.
-
The hardware DIP switch on the ESCM is set to
8.
This analog parameter is set according to the
actual requirements. The built-in analog
parameter is set here to monitor the ambient
temperature of the device.
For values and details of this parameter, see the
esc analog command.
When the ambient temperature of the device is
higher than 54°C, the device reports an alarm.
When the ambient temperature of the device is
lower than 6°C, the device reports an alarm.
3 Basic Configuration
136