5.3 SYSTEM
SPECIFICATION
PARAMETERS
-5.3.1 SETTING AXIS FOR USE (#1000)
Motionpack-llO
controls
up to 4 axes (X, Y, Z, S), and the axes to be used are designated
by
this parameter
as follows:
#1000
D7
D6
D5
D4
D3 I D2
D1
DO
I
0
0
t
$
Axis 1 (X) designated?
/
Axis 2 (Y) designated
?
Axis 3 (Z) designated
?
Axis 4 (S) designeted
?
Micro
PC module
?
Communication
function
(DNC)
?
Set "1" for use, and "0" for non-use.
Set "0" for no designation.
(Example)
Using
one axis
(X)
#1000
D7
D6
D5
D4
D3
D2
D1
DO
0
0
0
0
0
0
0
1
Using2axes_X
Z_ _1000
O7100o
0°_0 O4o O3o O21Ol1001
0 1
(1) Parameter
#1000-D4 is set only when there is a micro
PC module,
type JEFMC-B110.
(2) Parameter
#1000-D5 is set only when there is a motion
module
with the communication
function,
type JEFMC
-C027.