9.1.2.2
Power
Supply
for
PG
A 12 VDC
power
unit
is necessary
for feedback
unit
TFUE-[_DZC7
or TFUE-[B[NSAB.
A power
unit
meeting
the specifications
shown
in Table
9.3 should
be provided.
Table
9.3
Specifications
for
12 VDC
Power
Unit
Item
Specifications
Input Voltage
100/110 VAC, 50/60 Hz
Rated Voltage
12 V
Rated Current
200 mA (per 1 unit of PG)
Output Stability
Less than + 5 %
Ripple Noise
Less than 300 mVp-p
Leak Current
Less than 0.5 mA
Overcurrent
Protection
Provided
Working Temperature
0 to +55°C
Storing Temperature
-20°C
to +80°C
Relative
Humidity
30 to 90% (non-condensing)
t Input
Withstand voltage:
1,500 VAC, 1 minute
Frame
Insulation
Input
_
Output
Resistance:
Greater
than
100 MfI
at 500 VDC
I Output0
' Frame
Example
of model:
Type:
AYS
1201
Manufacturer:
Shindengen
Kogyo
KK
Input:
90 to 110 VAC,
47 TO 500 Hz
Output:
12 V, 1 A
As a compound
power
unit for both 5 V and 12 V, the following
model
is recommended.
Type:
CYG 500/01
Manufacturer:
Shindengen
Kogyo
KK
Input: 85to 132VAC,47to 63Hz
Output:
5V, 5A; 12 V, 2.5 A; -12 V, 0.4 A
167