Acceleration/Deceleration - YASKAWA MOTIONPACK-110 Descriptive Information

Motion controller for fa/fms for up to 3-axis drive
Table of Contents

Advertisement

5.6.1
ACCELERATION/DECELERATION
CONSTANT
(#1407,
#1607,
#1807,
#1501 TO #1503,
#1701 TO #1703,
#1901
TO #1903)
(Cont'd)
FEEDRATE
(mrn/s)
RAPID TRAVERSE
FEEDRATE V R
__
CHANGE
POINT
-
FEEDRATE
V=
2ND LINEAR
ACCEL/DECEL
CONSTANT
]
1ST LINEAR
L _,.
;_
/
_._ _r_.-""_
ACCEL
DECEL
CONSTANT
_""_JA
_--_ TIME
t (S)
Fig.
5.6
(Example)
When rapid
feedrate
= 12 m/min,
rising
time = 0.5 s, and
unit system
= 0.001 mm;
• 12 m/min
is converted
to the rate
per second
as follows:
12000 x _
= 200 mm/s
200
• Acceleration
from
0 to 12 m/min
is _
= 400 mm/s
2.
The value
set in the acceleration/deceleration
constant
parameter
is _
= 25.6.
Thus,
"25" is set.
NOTE
1. When determining
the acceleration/deceleration
constant,
measure
the
acceleration/deceleration
time of the machine
system,
and adopt
an
acceleration/deceleration
constant
that does not give acceleration/
deceleration
time
shorter
than
the measured
time.
2. When accelerating/decelerating
in one step, set the 1st and the 2nd accel/
decel
constant
to the same
value
and the change
point
feedrate
to 0.
3. When accelerating/decelerating
in 2 steps,
set the 1st accel/decel
constant
larger
than
the 2nd accel/decel
constant.
Set the change
point
feedrate
lower
than
the rapid
traverse
feedrate.
( a _> a 2, VR>V_)
(2) Exponential
Accel/Decel
Time
Constant
(#1407, #1607, #1807)
These
parameters
are for setting
the exponential
acceleration/deceleration
time con-
stant
for interpolation
motions.
Table
5.8
Parameter
No.
Description
Exponential
Accel/
#1407
(X)
Setting
range:
1 to
127
Decel
Time
Constants
#1607
(Y)
Setting
unit:
1 = 8 ms
#1807
(Z)
1OO