5.3.3
ME, SF, TF SIGNAL
DELAY
TIME
SETTING
(#1100) 0__ SET VALUE
<32767
When the M-code
read
signal
(MF),
T-code
read
signal
(TF)
or S-code
read
signal
(SF)
is
output
after
the M-BCD
code output
signal
(M,,
to M_8),
T-BCD
code output
signal
(T,,
to
T_
) or spindle
speed
command
with a delay,
the delay
time is set by this parameter.
The delay
can be set, with
"1" representing
8 ms.
For example,
setting
"2" means
a
delay
of 16 ms.
M-BCD CODE OUTPUT SIGNAL(Mll-M28)
T-BCD
CODE OUTPUT
SlGNAL(T11-T28)
SPINDLE
SPEED COMMAND
M-CODE READ SIGNAL(ME)
i"
t ms_l
T-CODE READ SIGNAL(TE)
S-CODE READ SIGNAL(SF)
Fig.
5.1
5.4 SPECIAL
PARAMETERS
5.4.1
POSITION
COMMAND
UNIT
SETTING
(#1557, #1558, #1757, #1758, #1957, #1958)
(1) Generally,
the position
detection
unit
(distance
per pulse)
is determined
by the drive
system
and
the position
detector.
Witn Motionpack-110,
two coefficients,
B/A
and A/B,
are used to match
the
position
command
unit
for the drive system
with
the position
detection
unit.
Fig.
5.2
shows
a block
diagram.
B/A
represents
the number
of output
pulses
per the minimum
input
unit (e. g.,
0.001 mm),
and
represents
the feed distance
of the machine
per pulse
of quadruple
PG.
Prior
to determining
the parameters,
B/A
and A/B
should
be calculated
frome
the specifications
of the machine
and
the detector
in advance,
and
x 16777216(integer
portion
only)
__
__ 100
A
B × 16777216(integer
portion
only)
(1-_0- __-_A B __100)
should
be set as the parameter
values.
Parameters
for B/A
for the X-, Y- and Z-axes
are #1557, #1757 and #1957, and
those
for A/B
are #1558, #1758 and #1958, respectively.
9O