7 Reference information
7.8 HILTI adhesive anchor
Continued
Installation
xx1400000487
For detailed information on installation see instruction for use given with the
package of the product.
For technical data for anchors in diamond drilled holes contact the Hilti Technical
advisory service.
Curing time for general conditions
Temperature of the base material
20 °C to 40 °C
10 °C to 19 °C
0 °C to 9 °C
-5 °C to - 1 °C
282
Curing time before anchor can be fully loaded
20 minutes
30 minutes
1 hour
5 hour
© Copyright 2015 - 2018 ABB. All rights reserved.
Product manual - IRBT 2005