Closing the grease pump
1
2
Installing a new grease cartridge
Respect the following instructions to replace the grease cartridge:
1
2
Product manual - IRBT 2005
3HAC051130-001 Revision: F
2.8.1 Replacing the grease cartridge in grease pump MEMOLUB
Action
Push firmly with one hand on top of the grease
pump. With the other hand, hold the black base
and turn counterclockwise.
Pull the transparent housing and open it.
Action
Hold the cranked black base, put on the trans-
parent housing and turn it clockwise.
When the closed position is reached you
should hear a "click".
Action
®
Open the MEMOLUB
as described before.
Pull-up the black rubber seal. Fill-in the
®
MEMOLUB
with a manual grease pump. This
manual operation is required only if the
®
MEMOLUB
has been used without a cart-
ridge, if the previous cartridge has run out of
grease. Place the pump nipple at the entry of
®
the MEMOLUB
, and pump until you see
grease coming out at the outlet. Two strokes
of the manual pump are usually enough.
© Copyright 2015 - 2018 ABB. All rights reserved.