ABB IRBT 2005 Product Manual page 280

Table of Contents

Advertisement

7 Reference information
7.8 HILTI adhesive anchor
Continued
M16 anchor
Recommended loads: concrete C 20/25 – fck,cube = 25 N/mm², anchor HAS
Shear VRd HAS [kN]
i
ii
Basic design tensile resistance
xx1400000488
Service temperature range
Hilti HVU adhesive may be applied in the temperature ranges given below. An
elevated base material temperature may lead to a reduction of the design bond
resistance.
Temperature range
Temperature range 1
Temperature range 2
Temperature range 3
i
ii
Continues on next page
280
The allowed range of embedment depth is shown in the setting details. The corresponding load
values can be calculated according to the simplified design method.
With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the
type of loading and shall be taken from national regulations.
Base material temper-
ature
-40 °C to +40 °C
-40 °C to +80 °C
-40 °C to +120 °C
Long-term elevated base material temperatures are roughly constant over significant periods of
time.
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a
result of diurnal cycling.
© Copyright 2015 - 2018 ABB. All rights reserved.
Maximum long term
Maximum short term
base material temper-
base material temper-
i
ature
ature
+24 °C
+40 °C
+50 °C
+80 °C
+72 °C
+120 °C
Product manual - IRBT 2005
3HAC051130-001 Revision: F
28,8
ii

Advertisement

Table of Contents
loading