Code
Absolute Data Lost 3.
(Amplifier Display: dL3)
6030
The absolute data of the encoder is lost. (Multi-
turn data fault in encoder)
Multi-turn Data Overflow
(Amplifier Display: AF)
6031
Excessive servo motor revolutions
Initial Error
(Amplifier Display: iE)
The initial position inside the encoder is not
established.
6032
【Additional Information】
This error may occur when the Power switch is
turned on while the servo motor is rotated by
hand.
Braking Transistor Error
(Amplifier Display: rH3)
The frequency of the command pulse inside the
6033
servo amplifier is high.
2. 00 [MHz] or a higher frequency is detected at
the inlet of the position deviation counter inside
the servo amplifier.
Inverter No Response
(Inverter Display: N/A)
6040
The communication connection between the
servo amplifier and the Control Board P109512
(QPM-290) for the B2 Stacker has not been
established.
Servo Amplifier Communication Failure
(Amplifier Display: N/A)
6041
The communication is not stable. A
communications data error occurred.
Drive Power Undervoltage
(Amplifier Display: N/A)
6042
The voltage of the power supplied to the servo
amplifier is insufficient.
SmartStacker User's Manual
Description and Causes
If an Error Code Is Displayed on SmartStacker
If this error occurs frequently, call your local
dealer.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
If this error occurs frequently, call your local
dealer.
Check if Q520a breaker is not tripped.
Check if Q520a breaker is not tripped.
If this error occurs frequently, call your local
dealer.
Solutions