Horizon Fitness SmartStacker User Manual page 241

Sheet cutter
Table of Contents

Advertisement

Code
B2 Stacker Stack Sheet Center Pusher Home
Positioning Error
2507
The M534 motor did not return to the home
position within the specified time after the start of
the home positioning.
B2 Stacker Stack Sheet End Pusher Home
Positioning Error
2508
The M535 motor did not return to the home
position within the specified time after the start of
the home positioning.
[SF] Suction head adjusting motor M940 home
positioning error
2601
The M940 motor did not return to the home
position within the specified time after the start of
the home positioning.
[SF] Table guide motor M941 home positioning
error
2602
The M941 motor did not return to the home
position within the specified time after the start of
the home positioning.
Inverter, Servo Amplifier: 3000-5999
A110 Inverter for 1st Regist Unit Transport Motor: 3100-3199
Inverter no response
(Inverter display: N/A)
The communication connection between the
3100
inverter, the reinforced insulation communication
board P110413 (QPW-943) and the control board
P109512 (QPM-290)for the 1st regist unit has not
been established.
Inverter communication error
(Inverter display: N/A)
3101
The control board P109512 (QPM-290) for the
1st regist unit received NAK several times from
the inverter.
Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
3110
During acceleration, the output current of the
inverter became double the rated current.
SmartStacker User's Manual
Description and Causes
If an Error Code Is Displayed on SmartStacker
Check if there is something to interrupt the home
positioning operation.
Close all the covers and make sure the
Emergency Stop button is released.
If this error occurs frequently, call your local
dealer.
Solutions