Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
4710
During acceleration, the output current of the
inverter became double the rated current.
Inverter alarm
Overcurrent during constant speed
(Inverter display: E.OC2)
4711
During constant-speed operation, the output
current of the inverter became double the rated
current.
Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
4712
During deceleration, the output current of the
inverter became double the rated current.
Inverter alarm
Overvoltage during acceleration
(Inverter display: E.OV1)
4720
During acceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter alarm
Overvoltage during constant speed
(Inverter display: E.OV2)
4721
During constant-speed operation, regenerative
energy has caused the main circuit DC voltage in
the inverter to exceed the specified value.
Inverter alarm
Overvoltage during deceleration
(Inverter display: E.OV3)
4722
During deceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter alarm
Inverter overload shut-off
(Inverter display: E.THT)
4730
The output current of the inverter has been more
than 150% of the rated current. Because the
output current is less than 200%, overcurrent
cutoff has not occurred. Output has been stopped
to protect the output transistor.