Horizon Fitness SmartStacker User Manual page 314

Sheet cutter
Table of Contents

Advertisement

If an Error Code Is Displayed on SmartStacker
Code
Inverter Alarm
Current Leakage Protection
(Inverter Display: E.GF)
5680
A ground fault has occurred in the power supply
circuit of the motor, and the inverter stopped the
output.
Inverter Alarm
Output Phase Failure Protection
(Inverter Display: E.LF)
5681
A phase failure has occurred in one of the three
output phases (U, V and W) from the inverter. The
output from the inverter has been stopped.
Inverter Alarm
Parameter Problem
5690
(Inverter Display: E.PE)
A parameter saved for the inverter is bad.
No Error Code for Inverter
(Inverter Display: N/A)
5699
An error which does not correspond to any of the
errors 5610 through 5698 has occurred on the
A590.
A510 Inverter for B2 Stacker Slope Transport Motor: 5700-5799
Inverter No Response
(Inverter Display: N/A)
The communication connection between
5700
the inverter, the Reinforced Insulation
Communication Board P110413 (QPW-943) and
the Control Board P109512 (QPM-290) for the B2
Stacker has not been established.
Inverter Communication Error
(Inverter Display: N/A)
5701
The Control Board P109512 (QPM-290) for the
B2 Stacker P109512 (QPM-290) received NAK
several times from the inverter.
Inverter Alarm
Overcurrent During Acceleration
(Inverter Display: E.OC1)
5710
During acceleration, the output current of the
inverter became double the rated current.
314
Description and Causes
Solutions
If this error occurs frequently, call your local
dealer.
Close all the covers and make sure the
Emergency Stop button is released.
If this error occurs frequently, call your local
dealer.
SmartStacker User's Manual

Advertisement

Table of Contents
loading

Table of Contents