Code
Inverter communication error
(Inverter display: N/A)
4201
The control board P109512 (QPM-290) for the
Merge Conveyor received NAK several times
from the inverter.
Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
4210
During acceleration, the output current of the
inverter became double the rated current.
Inverter alarm
Overcurrent during constant speed
(Inverter display: E.OC2)
4211
During constant-speed operation, the output
current of the inverter became double the rated
current.
Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
4212
During deceleration, the output current of the
inverter became double the rated current.
Inverter alarm
Overvoltage during acceleration
(Inverter display: E.OV1)
4220
During acceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter alarm
Overvoltage during constant speed
(Inverter display: E.OV2)
4221
During constant-speed operation, regenerative
energy has caused the main circuit DC voltage in
the inverter to exceed the specified value.
Inverter alarm
Overvoltage during deceleration
(Inverter display: E.OV3)
4222
During deceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.