Inverter alarm
Overvoltage during constant speed
(Inverter display: E.OV2)
4121
During constant-speed operation, regenerative
energy has caused the main circuit DC voltage in
the inverter to exceed the specified value.
Inverter alarm
Overvoltage during deceleration
(Inverter display: E.OV3)
4122
During deceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter alarm
Inverter overload shut-off
(Inverter display: E.THT)
4130
The output current of the inverter has been more
than 150% of the rated current. Because the
output current is less than 200%, overcurrent
cutoff has not occurred. Output has been stopped
to protect the output transistor.
Inverter alarm
Motor overload shut-off
(Inverter display: E.THM)
4134
The electronic thermal alarm built into the
inverter has detected an overload of the motor of
overheating in the motor due to poor cooling, and
has stopped the output from the inverter.
Inverter alarm
Fin overheat
(Inverter display: E.FIN)
4140
The cooling fins on the inverter have overheated,
so the temperature sensor has stopped the
output from the inverter.
Inverter alarm
Input phase failure
(Inverter display: E.ILF)
4152
A phase failure has occurred in one of the three
input phases (R, S and T) to the inverter, or there
was a big difference in voltage between the input
phases. This has stopped the output from the
inverter.
SmartStacker User's Manual
Description and Causes
If an Error Code Is Displayed on SmartStacker
If this error occurs frequently, call your local
dealer.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
If this error occurs frequently, call your local
dealer.