Horizon Fitness SmartStacker User Manual page 306

Sheet cutter
Table of Contents

Advertisement

If an Error Code Is Displayed on SmartStacker
Code
Parameter problem
(Inverter display: E.PE)
5190
A parameter saved for the inverter is bad.
No error code for inverter
(Inverter display: N/A)
5199
An error which does not correspond to any of the
errors 5100 through 5199 has occurred on the
A451 inverter for delivery conveyor motor.
A460 Inverter for Transport Motor for Output Shift: 5200-5299
Inverter no response
(Inverter display: N/A)
The communication connection between the
5200
inverter, the short circuit board P109111 (QPW-
936), the reinforced insulation communication
board P110413 (QPW-943), and the control
board P109512 (QPM-290) for the Merge Stacker
has not been established.
Inverter communication error
(Inverter display: N/A)
5201
The control board P109512 (QPM-290) for the
Merge Stacker P109512 (QPM-290) received
NAK several times from the inverter.
Overcurrent during acceleration
(Inverter display: E.OC1)
5210
During acceleration, the output current of the
inverter became double the rated current
Overcurrent during constant speed
(Inverter display: E.OC2)
5211
During constant-speed operation, the output
current of the inverter became double the rated
current.
Overcurrent during deceleration
(Inverter display: E.OC3)
5212
During deceleration, the output current of the
inverter became double the rated current.
306
Description and Causes
Solutions
If this error occurs frequently, call your local
dealer.
Close all the covers and make sure the
Emergency Stop button is released.
If this error occurs frequently, call your local
dealer.
SmartStacker User's Manual

Advertisement

Table of Contents
loading