Horizon Fitness SmartStacker User Manual page 317

Sheet cutter
Table of Contents

Advertisement

Code
Inverter Alarm
Parameter Problem
5790
(Inverter Display: E.PE)
A parameter saved for the inverter is bad.
No Error Code for Inverter
(Inverter Display: N/A)
5799
An error which does not correspond to any of the
errors 5700 through 5798 has occurred on the
A510.
A540 Inverter for B2 Stacker Stack Table Up/Down Motor: 5900-5999
Inverter No Response
(Inverter Display: N/A)
The communication connection between
5900
the inverter, the Reinforced Insulation
Communication Board P110413 (QPW-943) and
the Control Board P109512 (QPM-290) for the B2
Stacker has not been established.
Inverter Communication Error
(Inverter Display: N/A)
5901
The Control Board P109512 (QPM-290) for the
B2 Stacker P109512 (QPM-290) received NAK
several times from the inverter.
Inverter Alarm
Overcurrent During Acceleration
(Inverter Display: E.OC1)
5910
During acceleration, the output current of the
inverter became double the rated current.
Inverter Alarm
Overcurrent During Constant Speed
(Inverter Display: E.OC2)
5911
During constant-speed operation, the output
current of the inverter became double the rated
current.
Inverter Alarm
Overcurrent During Acceleration
(Inverter Display: E.OC1)
5912
During deceleration, the output current of the
inverter became double the rated current.
SmartStacker User's Manual
Description and Causes
If an Error Code Is Displayed on SmartStacker
If this error occurs frequently, call your local
dealer.
Close all the covers and make sure the
Emergency Stop button is released.
If this error occurs frequently, call your local
dealer.
Solutions