Horizon Fitness SmartStacker User Manual page 318

Sheet cutter
Table of Contents

Advertisement

If an Error Code Is Displayed on SmartStacker
Code
Inverter Alarm
Overvoltage During Acceleration
(Inverter Display: E.OV1)
5920
During acceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter Alarm
Overvoltage During Constant Speed
(Inverter Display: E.OV2)
5921
During constant-speed operation, regenerative
energy has caused the main circuit DC voltage in
the inverter to exceed the specified value.
Inverter Alarm
Overvoltage During Deceleration
(Inverter Display: E.OV3)
5922
During deceleration, regenerative energy has
caused the main circuit DC voltage in the inverter
to exceed the specified value.
Inverter Alarm
Inverter Overload Shut-off
(Inverter Display: E.THT)
5930
The output current of the inverter has been more
than 150% of the rated current. Because the
output current is less than 200%, overcurrent
cutoff has not occurred. Output has been stopped
to protect the output transistor.
Inverter Alarm
Motor Overload Shut-off
(Inverter Display: E.THM)
5931
The electronic thermal alarm built into the
inverter has detected an overload of the motor of
overheating in the motor due to poor cooling, and
has stopped the output from the inverter.
Inverter Alarm
Fin Overheat
(Inverter Display: E.FIN)
5940
The cooling fins on the inverter have overheated,
so the temperature sensor has stopped the
output from the inverter.
318
Description and Causes
Solutions
If this error occurs frequently, call your local
dealer.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
SmartStacker User's Manual

Advertisement

Table of Contents
loading

Table of Contents