Code
Vacuum Blower Motors M521 through M523
Failure
1540
The error signal from the M521 through M523
vacuum motors is received by the control board.
Separation Air Motor M529 Failure
1543
The error signal from the M529 separation air
motors is received by the control board.
Deposition of K901 interlock contactor 1
Even though the S901 Emergency Stop button or
1601
Emergency Stop button on a downstream device
is pressed, the contact points of K901 are still
closed.
Deposition of K902 interlock contactor 2
Even though the S901 Emergency Stop button or
1602
Emergency Stop button on a downstream device
is pressed, the contact points of K902 are still
closed.
Deposition of K903 interlock contactor 3
1603
Even though the S901 Emergency Stop button is
pressed or the contact points of S902 is open, the
contact points of K903 are closed.
K903 interlock contactor 3 function error
Though the interlock circuit is closed (=all the
1604
covers close and S901 Emergency Stop button is
not pressed), the contact points for terminals 21
and 22 on K903 are open.
K902 interlock contactor 2 function error
Though the interlock circuit is closed (=all the
1698
Emergency Stop buttons are not pressed), the
contact points for terminals 21 and 22 on K902
are open.
K901 interlock contactor 1 function error
Though the interlock circuit is closed (=all the
1699
Emergency Stop buttons are not pressed), the
contact points for terminals 21 and 22 on K901
are open.
SmartStacker User's Manual
Description and Causes
If an Error Code Is Displayed on SmartStacker
If this error occurs frequently, call your local
dealer.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
Solutions