2. CHECK POWER SUPPLY AND
GROUND CIRCUIT
No.
1
CHECK POWER SUPPLY FOR COMBINA-
TION METER.
1) Remove combination meter. <Ref. to IDI-
15, REMOVAL, Combination Meter Assem-
bly.>
2) Disconnect combination meter harness
connector.
3) Turn ignition switch to ON.
4) Measure voltage between combination
meter connector and chassis ground.
Connector & terminal
Normal meter:
(i12) No. 3 (+) — Chassis ground (−):
Luminescent meter:
(i10) No. 8 (+) — Chassis ground (−):
(i11) No. 5 (+) — Chassis ground (−):
2
CHECK POWER SUPPLY FOR COMBINA-
TION METER.
Measure voltage between combination meter
connector and chassis ground.
Connector & terminal
Normal meter:
(i12) No. 7 (+) — Chassis ground (−):
Luminescent meter:
(i10) No. 9 (+) — Chassis ground (−):
(i12) No. 1 (+) — Chassis ground (−):
3
CHECK GROUND CIRCUIT OF COMBINA-
TION METER.
1) Turn ignition switch to OFF.
2) Measure resistance of harness between
combination meter connector and chassis
ground.
Connector & terminal
Normal meter:
(i10) No. 20 (+) — Chassis ground (−):
Luminescent meter:
(i10) No. 18 (+) — Chassis ground (−):
4
CHECK GROUND CIRCUIT OF COMBINA-
TION METER.
Measure resistance of harness between com-
bination meter connector and chassis ground.
Connector & terminal
Normal meter:
(i11) No. 16 (+) — Chassis ground (−):
Luminescent meter:
(i11) No. 7 (+) — Chassis ground (−):
COMBINATION METER SYSTEM
S907607A1001
Step
Check
Is the voltage more than
10 V?
Is the voltage more than
10 V?
Is the resistance less than
10 Ω?
Is the resistance less than
10 Ω?
IDI-7
Instrumentation/Driver Info
Yes
Go to step 2.
Check harness for
open or short
between ignition
relay and combi-
nation meter.
Go to step 3.
Check harness for
open or short
between fuse and
combination
meter.
Go to step 4.
Repair wiring har-
ness.
Replace combina-
Repair wiring har-
tion meter.
ness.