Changing The Control Method - Mitsubishi Electric FR-A820-00046 Instruction Manual

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Control method
5.2.2

Changing the control method

Set the control method and control mode.
V/F control, Advanced magnetic flux vector control, Real sensorless vector control, Vector control,
and PM sensorless vector control are the control methods available for selection.
The control modes are speed control, torque control, and position control. These are set when se-
lecting Advanced magnetic flux vector control, Real sensorless vector control, Vector control, and PM
sensorless vector control. Select a control mode from speed control mode, torque control mode and
position control mode under Real sensorless vector control or vector control. The initial setting is V/
F control.
When using an IPM motor MM-CF, simply performing the IPM parameter initialization enables the PM
sensorless vector control and selects the speed control and position control.
● Select a control method and control mode by using Pr. 800 (Pr. 451) "Control method selection".
● The control mode can be switched using the mode switching signal (MC).
Pr.
71
C100
80
C101
81
C102
83
C104
84
C105
800
G200
5 - 56
Initial
Name
value
Applied motor
Motor capacity
Number of motor poles
200/400 V
Rated motor voltage
Rated motor frequency
Control method selection
Setting range
0 to 6, 13 to 16, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54, 70, 73, 74,
0
330, 333, 334, 8090,
8093, 8094, 9090, 9093,
9094
0.4 to 55 kW
9999
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
9999
0 to 1000 V
10 to 400 Hz
9999
9999
0 to 6
9
10 to 12
13, 14
20
20
100 to 106
109
110 to 112
110, 113, 114
Description
By selecting a standard motor or constant-
torque motor, the thermal characteristic and
motor constant of each motor are set.
Set the applied motor capacity.
V/F control
Set the number of motor poles.
V/F control
Set the rated motor voltage (V).
Set the rated motor frequency (Hz).
The setting value of Pr. 3 "Base frequency" is
used.
Vector control
Vector control test operation
Real sensorless vector control
PM sensorless vector control
V/F control
(Advanced magnetic flux vector control)
Vector control
Vector control, PM
sensorless vector
control test operation
Fast-response
operation
Real sensorless vector
control
PM sensorless vector
control
Parameters

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents